Forum Post: RE: Hammer - When will batch calculation be implemented?
Hi Scott, the scenarios were set up for a sensitivity study involving 5 independent variables. The only way to reduce the number of scenarios is to reduce the number of samples in each variable - but...
View ArticleComment on Haestad Product Line: New Version Releases of WaterGEMS, WaterCAD,...
When will SewerCAD database engine be converted to SQLite instead of MS ADE (like WaterCAD)?
View ArticleWiki Page: The specified module could not be found
Applies To Product(s): Bentley SewerGEMS, Bentley WaterGEMS Version(s): 08.11.03.77 Environment: N/A Area: Other Subarea: Original Author: Terry Foster, Bentley Technical...
View ArticleForum Post: How to monitor line pressure developed if a valve in downstream...
In this simple network, how to monitor line pressure developed (pipe dia 50NB, 5m) in BENTLEY HAMMER, (which is a part of the network) if the valve is partially closed and the pump (2hp) is running...
View ArticleForum Post: RE: Hammer - When will batch calculation be implemented?
Hi Sven, I have updated the blog with the newer version of the tool which let's you run multiple instances and has ability to de/select all scenarios at once....
View ArticleForum Post: Questions related to tank level control and WTP simulation
All, I have a couple questions related to independent challenges with my WaterGEMS model. 1. I have a number of controls set up to allow the tanks in my system to fill. These controls are set up with...
View ArticleForum Post: RE: Questions related to tank level control and WTP simulation
Files were uploaded successfully. Scott
View ArticleForum Post: RE: Stop Control Structure Adjacent to Outfall
Hello Kobalt, Your workaround sounds reasonable. I would recommend using the "bolted" option in the manhole, or use a transition node instead, and make sure the downstream pipe next to the outfall...
View ArticleWiki Page: Understanding Known Flows
Applies To Product(s): Bentley StormCAD, Bentley SewerCAD, Bentley SewerGEMS Version(s): 08.11.0X.0X. Environment: N\A Area: Modeling Subarea: N\A Original Author: Bentley...
View ArticleForum Post: RE: Questions related to tank level control and WTP simulation
For anyone you might be interested, with the first issue, removing a set of controls on the FCV immediately downstream of the pump helped with the issue. A user notification was still generated that...
View ArticleForum Post: RE: How to monitor line pressure developed if a valve in...
Hello, You can try viewing the time history graph (found in the Transient Results Viewer) to see what is happening at the valve over time. You can add the valve as a report point by opening the...
View ArticleWiki Page: Error launching WaterCAD and WaterGEMS: Failed to load managed...
Applies To Product(s): Bentley WaterCAD, Bentley WaterGEMS Version(s): 08.11.xx.xx Environment: N\A Area: Other Subarea: N\A Original Author: Scott Kampa, Bentley Technical Support Group Problem...
View ArticleWiki Page: Why are the results in the Hydraulic Reviewer showing large...
Applies To Product(s): Bentley SewerGEMS Version(s): 08.11.xx.xx Environment: N\A Area: Output and Reporting Subarea: N\A Original Author: Scott Kampa, Bentley Technical Support Group Problem...
View ArticleForum Post: Flushing II (Pipe Run)
Hello As photos attched, there is a ‘Flushibg’ has been defined for the network. As you see P-4 and ISO-2 is closed and water must flows from Pipe Run path (from ‘Reservoir’ to P-1 and P-2 and P-3...
View ArticleForum Post: Flushing III (Editing an Event)
Hello While working with ‘Flushing’, When an Event is defined then it is impossible to edit the Event’s elements (I mean to add an element to it). And if you have forgotten to select an element, then...
View ArticleForum Post: Pump Failure Simulations
I am using sewergems V8i and trying to simulate failure at lift stations and the cause effect of the failure. I know I would have to use the control sets in assigning when the pump should go off. But...
View ArticleForum Post: RE: Flushing III (Editing an Event)
Hi Simbaa, You can update the elements (in a Unidirectional Event). Click on the desired Event node in the treeview; on the right side of the form, you will see a table with the list of selected...
View ArticleForum Post: Reports
Hello, I'm using SewerGEMS latest version 08.11.03.84 . I would like to be able to issue a report per each node/conduit/pressure pipe with following data: ID Diameter Length Slope Velocity Headloss...
View ArticleForum Post: Flow
Hello, I'm using SewerGEMS latest version 08.11.03.84 . 1) What is the difference between "Flow (System known)" , "Flow (System sanitary)" and just "Flow"? 2) In Wet Well properties pane there is a...
View Article