Forum Post: RE: Questions related to tank level control and WTP simulation

$
0
0
For anyone you might be interested, with the first issue, removing a set of controls on the FCV immediately downstream of the pump helped with the issue. A user notification was still generated that said that the FCV could not deliver flow, but this was only due to the upstream pump having an "off" status. For the second issue, adjusting the calculation options helped achieve better results. For unbalanced network issues, the following support solution is a good resource: How can a user fix the WaterGEMS/WaterCAD error message "network unbalanced"? Regards, Scott Kampa Bentley Technical Support