      Applies To        Product(s): Bentley SewerGEMS, Bentley WaterGEMS   Version(s): 08.11.03.77   Environment:  N/A   Area:  Other   Subarea:    Original Author: Terry Foster, Bentley Technical Support Group                   Error or Warning Message When trying to open any model (lesson file, sample file, or existing project) with a .dxf background layer or when importing .dxf through Modelbuilder , the following error appears: The specified module could not be found. (Exception from HRESULT: 0x8007007E)   How to Avoid Option 1  Make sure that there is a RealDWG folder in the program installation folder.  This is installed with the software.  If this folder is missing, download and re-install the software again. Option 2 If RealDWG is not the issue, check if you have had a video card driver update recently.  If so, try rolling that back, or upgrade to a newer card version.  (We have seen this with at least one case with an HP driver for Intel HD 400.)  One way to check if it is the video card driver is to boot your computer in safe mode.  This will use a different, generic driver.  If you are able to open the project in safe mode, this helps to confirm it is a video driver issue. See Also SewerCAD SS3, civilStorm SS3, StormCAD SS3, WaterGEMS SS4, WaterCAD SS4, HAMMER SS4