Forum Post: RE: How to monitor line pressure developed if a valve in downstream is partially closed and pump is running continuously

$
0
0
Hello, You can try viewing the time history graph (found in the Transient Results Viewer) to see what is happening at the valve over time. You can add the valve as a report point by opening the transient calculation options. You can choose to add all or a select number of points as report points. After computing the model, you can graph the results. You can check the section "How does the Transient Results Viewer work and how can I use it to view my results?" at the following link for more details on how to use the Transient Results Viewer: communities.bentley.com/.../3031.general-hammer-v8i-faq.aspx For the line pressure, what are you looking for there? Note that to see the results when the valve is closed, you will need to adjust the valve status or use an operating rule to have the valve move from partially open to closed. Regards, Scott Kampa Bentley Technical Support