Quantcast
Channel: OpenFlows | Water Infrastructure
Browsing all 39611 articles
Browse latest View live

Comment on Opening FlowMaster, the following error occurs:...

Does this apply to Flowmaster SS1 8.11.01.03?

View Article


Comment on Opening FlowMaster, the following error occurs:...

Yes, see Option 2- "if you have a version later than 08.01.071.00"

View Article


Forum Post: Why does some of TCV's in my model do not work?

I have a TCV in my model which do not work, for example when i close it, there is still a pressure in the node. But for some TCV's in my model they are all working. I tried to redraw all the pipes and...

View Article

Forum Post: RE: 48 hrs. EPS run in WaterGEMS

Hi Akshaya: Thanks for your detailed answer.  You have guessed correctly that I want to run the model for 2 days, however only for hydraulics and not for water quality.  What I want to see is the...

View Article

Forum Post: RE: Hammer model setup/errors

Hi Scott, Thanks for the quick responses. I tried 0.01 s time step. The simulation ran fine but it took approx. 5 minutes. I then tried 0.02s, but I got the same error message. I can not afford 5...

View Article


Forum Post: RE: WaterCAD and WaterGEMS Compatibility issue

From the exception log it's Intel (on-board) graphics; Mobile Intel(R) 965 Express Chipset Family (Microsoft Corporation - WDDM 1.1) Maen, You show the screen after the error and the Tools menu looks...

View Article

Forum Post: RE: 48 hrs. EPS run in WaterGEMS

Controls with conditions based on hydraulic parameters (e.g., tank level) do not need any alteration. Controls based on time depend on whether they are based on simulation time (time from start [of...

View Article

Forum Post: Alternative to FCV in EPS

Hi, In EPS run I use FCVs to control the inlet flows to Tanks.  What happens in most of the times is that FCVs introduces large head losses in the line. As per WaterGEMS this is expected since FCVs...

View Article


Forum Post: RE: 48 hrs. EPS run in WaterGEMS

Hi Dr. PK, As Wayne suggested, you could use the Time based control to trigger the Control at a particular time. I, personally though, am less fan of Time Based control as no matter what goes in the...

View Article


Forum Post: RE: Alternative to FCV in EPS

Hi Dr. PK, If you are not seeing such a drop in HGL (or Pressure) at FCV in the system then I would question, why/how are you gutting a high flow in that line? May be pump is adding too much flow? I...

View Article

Forum Post: RE: Why does some of TCV's in my model do not work?

Hello, What was the name of the file uploaded? I will take a look. Also, to which TCV are you referring? Dan

View Article

Forum Post: RE: 48 hrs. EPS run in WaterGEMS

To give an example of what Wayne and Akshaya mentioned, take a look at the Example1.wtg file included with the program. There are controls to turn a pump on and off based on the elevation of a tank....

View Article

Forum Post: RE: WaterCAD and WaterGEMS Compatibility issue

Thanks every one,, my problem is solved! but first let me explain how Jesse Dringoli I started Windows in safe mode and WaterCAD worked perfectly Wayne Hartell I tried to do what you said but by...

View Article


Forum Post: RE: 48 hrs. EPS run in WaterGEMS

Thanks to all for inputs.  I have a other difficulty.  The client I face here in India most of them do not understand EPS.  They want to see results based on pumping schedule and valve setting....

View Article

Forum Post: RE: Alternative to FCV in EPS

Hi Akshaya: I have to show actual pump operating and valve operating schedule in model to my client.  Hence, I have to follow time scale on which pump is going to operate in the field.  In this case,...

View Article


Forum Post: RE: Alternative to FCV in EPS

Hi Dr. PK, As you know, we cannot just control one parameter. If we restrict flow, we will see drop in head. So, I feel like there must be something else that needs attentions. The flows are matching...

View Article

Wiki Page: Opening FlowMaster, the following error occurs:...

      Applies To        Product(s): Bentley FlowMaster   Version(s): 08.01.071.00   Environment:  N/A   Area:  Other   Subarea:    Original Author: Terry Foster, Bentley Technical Support Group...

View Article


Wiki Page: CivilStorm Menu not loading in CivilStorm for Microstation with a...

Applies To Product(s): CivilStorm, Bentley StormCAD, Bentley SewerGEMS, Bentley PondPack, Bentley WaterCAD, Bentley WaterGEMS Version(s): 08.11.XX.XX Environment: Microstation Area: Installation...

View Article

Wiki Page: Haestad product menu is not showing up when integrated with...

      Applies To        Product(s): Bentley WaterCAD, Bentley WaterGEMS, Bentley SewerGEMS, Bentley SewerCAD, Bentley CivilStorm, Bentley StormCAD, Bentley HAMMER, Bentley PondPack   Version(s):...

View Article

Wiki Page: What is the process a Haestad product takes to integrate with...

      Applies To        Product(s): Bentley StormCAD, Bentley WaterGEMS, Bentley WaterCAD, Bentley SewerGEMS, Bentley SewerCAD, Bentley CivilStorm, Bentley HAMMER, Bentley PondPack   Version(s):...

View Article
Browsing all 39611 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>