Forum Post: RE: WaterGems Model of Water Tank - Level Drops Faster Than Flow...
Hello Ken, In addition to Craig's response, what is the operating range you have specified for tank operation? Along with the "reporting time" it would be good to check the tank levels you have...
View ArticleWiki Page: Can StormCAD import an Autodesk (AutoCAD) storm sanitary analysis...
Product(s): StormCAD Version(s): 08.11.06.83 Area: Layout and Data Input Problem Description Can StormCAD import an Autodesk (AutoCAD) storm sanitary analysis (SSA) file? Background StormCAD cannot...
View ArticleForum Post: Conduit Invert(start) & Invert(Stop) showing reverse compare to...
Sir, I have created sewer model in SewerGEMS using model builder(Conduit, MH & Outfall) function. After designing network, I found many conduit start node & stop node indication was showing in...
View ArticleForum Post: RE: Conduit Invert(start) & Invert(Stop) showing reverse compare...
Hello Rohit, When building the model using Modelbuilder, start and stop nodes will be taken as per direction using which they are drawn in source file say AutoCAD drawing. E.g. if line is drawn from A...
View ArticleForum Post: How to use wet well & pump combination in SewerGEMS?
Dear Sir/Madam, I am designing sewerage network using SewerGEMS. Right now I am using outfall as a pumping station instead of our Wet Well. Collected sewage flow at outfall/pumping station I need to...
View ArticleForum Post: RE: How to use wet well & pump combination in SewerGEMS?
Hello Rohit, It is always better to model the conditions as they are on field, so if you are lifting the water from wet well into next gravity manhole using pump stations, then you should model pump ,...
View ArticleWiki Page: How does the license size work for the different Haestad storm and...
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): 08.11.XX.XX Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How does the licensing work for the...
View ArticleWiki Page: Modeling an Ideal Pump (Outflow matches Inflow)
Product(s): SewerGEMS, CivilStorm Version(s): As of 10.01.01.04 Area: Modeling Problem Is it possible to model an "Ideal" pump, where the outflow from the pump will match the inflow? This might be used...
View ArticleForum Post: RE: How to use wet well & pump combination in SewerGEMS?
Rohit, Can you tell us a bit more about why you are wanting to directly pass the wetwell inflow into the downstream receiving gravity manhole? Are you trying to assume an "ideal pump" for preliminary...
View ArticleProduct release (estimated) - Storm/Sewer
Estimated release date for Storm and Sewer CONNECT Edition Update 2: end of September, 2018. Subject to change. This applies to the following products: SewerGEMS SewerCAD CivilStorm StormCAD How can I...
View ArticleWiki Page: Should the EPANET solver and the WaterGEMS/CAD solver give the...
Applies To Product(s): WaterGEMS, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Should the EPANET solver...
View ArticleWiki Page: How do you create an IF / THEN / ELSE statements using Formula...
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley...
View ArticleForum Post: RE: How to sort the graphs in the new version of WaterGEMS...
Hi Yashodhan, Thanks for your response. The version we are currently using is 10.00.00.55 (22/5/2017 build), in which all graphs can be sorted using the label. The new version we are testing is...
View ArticleForum Post: Conduit Invert(start) & Invert(Stop) showing reverse compare to...
Split from : communities.bentley.com/.../conduit-invert-start-invert-stop-showing-reverse-compare-to-its-flow-direction Can Bentley add a new function in the FlexTable called " Reverse", so we can do...
View ArticleForum Post: RE: Conduit Invert(start) & Invert(Stop) showing reverse compare...
Hello Mohammad, Do you wish to "reverse" the values after filtering out the negative values? This can be done in two steps; 1. Filter out the negative flow values by running a custom query using...
View ArticleForum Post: RE: Conduit Invert(start) & Invert(Stop) showing reverse compare...
Hello Mohamad, I see that you had replied to another post about negative slope, where user wanted to reverse start and stop nodes of pipes with negative slopes. At the moment which can be done through...
View ArticleForum Post: StormCAD
Hello, I have two queries: 1) At a Manhole three incoming conduits are there and one conduit is leaving away from the same manhole to a outfall. Total discharge incoming from these three conduits is...
View Article