Wiki Page: Using the Post Calculation Processor
Applies To Product(s):WaterGEMS, WaterCAD Version(s):V8i or V8 XM Environment: N/A Area: N/A Subarea: N/A Original Author:Scott Kampa, Bentley Technical Support Group OverviewThe purpose...
View ArticleWiki Page: WaterGEMS For ArcGIS [FAQ]
Applies To Product(s):Bentley WaterGEMS Version(s):V8 XM and V8i Environment: N/A Area: N/A Subarea: N/A Original Author:Jesse Dringoli, Bentley Technical Support Group How do I open an...
View ArticleWiki Page: WaterGEMS V8 Automated Fire Flow [FAQ]
Applies To Product(s):Bentley WaterGEMS, Bentley WaterCAD Version(s):V8 XM, V8i Environment: N/A Area: N/A Subarea: N/A Original Author:Jesse Dringoli, Bentley Technical Support Group...
View ArticleWiki Page: WaterGEMS V8 Modeling [FAQ]
Applies To Product(s):Bentley WaterGEMS, Bentley WaterCAD Version(s):V8 XM, V8i Environment: N/A Area: N/A Subarea: N/A Original Author:Jesse Dringoli, Bentley Technical Support Group...
View ArticleWiki Page: What's new in WaterCAD and WaterGEMS V8i SELECTseries 2?
Applies To Product(s):Bentley WaterCAD, Bentley WaterGEMS Version(s):V8i SELECTseries 2 (08.11.02.31) Environment: N/A Area: N/A Subarea: N/A Original Author:Jesse Dringoli, Bentley Technical...
View ArticleWiki Page: What's New with WaterGEMS/WaterCAD V8i SELECTSeries 3
Applies To Product(s):Bentley WaterGEMS and Bentley WaterCAD Version(s):V8i SELECTseries 3 (08.11.03.17) Environment: N/A Area: N/A Subarea: N/A Original Author:Scott Kampa, Bentley Technical...
View ArticleWiki Page: What's New with WaterGEMS/WaterCAD V8i SELECTSeries 4?
Applies To Product(s):Bentley WaterGEMS Version(s):V8i SELECTseries 4 (08.11.04.50) Environment: N/A Area: N/A Subarea: N/A Original Author:Akshaya Niraula, Bentley Technical Support Group...
View ArticleForum Post: Re: Sewergems PERCENT FULL CONTRAINT TYPE (TABLE) Problem
Hello,This is appears to be occurring because the default design constraints for certain elements are being violated. I will note that I tested this in each of the last three versions of SewerCAD...
View ArticleForum Post: SewerGems - Changing Storm Start Time
Fellow users,I am modeling a complex sanitary sewer system in SewerGems. The primary problem in the system has been inflow and infiltration, so I am modeling catchments for each sewershed with RTK...
View ArticleForum Post: Re: Stop trace at some elements
Hi, Let’s try something like this as I didn’t find a clear way of modeling what you are trying. (Based on your description, network downstream of the booster pump will receive water from that...
View ArticleForum Post: Re: Export StormCAD V8i to PowerCivil V8i Drainage - Missing...
Hi John,In this case, it looks like some of your Catch Basins are probably set to Full Capture, Percent Capture, or one of the other Inlet Type options under the Catch Basin Properties. Make sure all...
View ArticleForum Post: Re: Epanet
What is the elevation of that node? If it's 14m then here's the math:9.9 + 14 = 23.9(It's good to create a new Forum post with a descriptive topic, if you have a different question so that it may help...
View ArticleForum Post: Re: Hydraulic check valve problem
Hi Bruce,It sounds like you have a mechanical problem and if so, you _may_ not hear any recommendations. What about contacting the manufacturer?If it's a hydraulic modeling issue then please let us...
View ArticleForum Post: Re: Using Epanet function ENgetlinkvalue
Hi Giancarlo,Not all of us here are familiar with EPANET programming side so if you could let us know what you are trying to get from WO API, we might be able to help you. Honestly, I am not sure what...
View ArticleForum Post: Re: WaterCAD FCV Control
Mark,Thanks again for your advice.After removing the junction with negative flow and changing the initial setting of FCV to closed, FCV started to open and closed at longer cycle (> 24 hurs),...
View ArticleWiki Page: SELECTsupport TechNotes And FAQs
Key:CS – Client Server ArticleFAQ – Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoThe following TechNotes and FAQs are provided as a reference by Bentley's...
View ArticleWiki Page: Energy Cost Analysis in WaterGEMS V8i SELECTseries 4
Applies To Product(s):WaterGEMS, WaterCADVersion(s):V8i SelectSeries 4 or laterEnvironment: N/AArea: N/ASubarea: N/AOriginal Author:Dan Iannicelli, Bentley Technical Support Group OverviewThis...
View ArticleWiki Page: Flushing in WaterGEMS/CAD Select Series 4
Applies To Product(s):Bentley WaterGEMS/WaterCAD Version(s):V8i SELECTseries 4 (08.11.04.50) Environment: N/A Area: Other Subarea: N/A Original Author:Terry Foster, Bentley Technical Support...
View ArticleWiki Page: Importing Demands From A Spreadsheet [TN]
Applies To Product(s):Bentley WaterCAD V8i, Bentley WaterGEMS V8i Version(s):08.11.XX.XX Environment: N/A Area: Layout and Data Input Subarea: N/A Original Author:Jesse Dringoli, Bentley...
View Article