Wiki Page: CivilStorm TechNotes and FAQs

This article provides a list of in-depth TechNotes and FAQs for Bentley CivilStorm. To search within this page, press [Ctrl]+F. Frequently Asked Questions CivilStorm General FAQs Modeling Creating...

View Article


Wiki Page: Using the Scenario Energy Cost tool in SewerGEMS, SewerCAD and...

Product(s): SewerGEMS, SewerCAD, CivilStorm Version(s): 10.00.00.40 and later Area: Modeling Overview This article explains how to use the Scenario Energy Cost tool in SewerGEMS, SewerCAD, CivilStorm...

View Article


Blog Post: Easy pump control creation with the Control Wizard

Have you ever had trouble keeping track of controls or wish there was a faster way to create them? Did you know that the In this short video, see how easy it can be to create pump controls with the...

View Article

Forum Post: Negative Pressures in Pipe

My model consists of a reservoir from a higher elevation supplying water to two tanks at a lower elevation. The pipe leading to the tanks keeps going to a negative pressure despite the inclusion of air...

View Article

Forum Post: RE: Negative Pressures in Pipe

I've uploaded the file NegativePressures.sqlite through the secure file upload option for your review.

View Article


Forum Post: RE: Negative Pressures in Pipe

The correction depends on why you have having negative pressure. If it is because the pipes are at a higher elevation than the surrounding tanks, you may need to pump over that high point. If it is...

View Article

Forum Post: RE: Negative Pressures in Pipe

The order of elevation is as follows: Reservoir > Pipe > Tank so I don't think I need to pump. In terms of head loss, I'm only pushing less than 2MGD through an 8-inch pipe. It would seem...

View Article

Forum Post: RE: Negative Pressures in Pipe

I looked at the model and animated the profile. At times the flow to the lower tanks is so great that the HGL drops below the ground. This is an elevation problem. The HGL at the reservoir is at...

View Article


Forum Post: RE: Negative Pressures in Pipe

I agree that the reservoir HGL is too low. I'll have to check on that. However, are the high flows to the tank realistic?

View Article


Forum Post: i have updated the model

good morning regards to my yesterday question i have updated the model (WATERGEMS) communities.bentley.com/.../130050 from that model i would like to see the pressure curve for junction 1 during 24 hrs...

View Article

Forum Post: RE: Negative Pressures in Pipe

Once again, you have several options. 1. The tanks are too low relative to the source. They will fill and either overflow or if you have a altitude valve, shut off. Raise the top of the tanks so you...

View Article

Wiki Page: Troubleshooting negative pressures at pumps, junctions, & other...

Applies To Product(s): WaterGEMS, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX Area: Modeling Original Author: Dan Iannicelli , Mark Pachlhofer, and Jesse Dringoli, Bentley Technical Support...

View Article

Forum Post: Darwin designer options

Hello all. I am carrying out an optimization run using darwin designer.I am just curious to know if there is a way you could use the tank size(Volume) as a decision variable in addition to the pipe...

View Article


Forum Post: RE: Darwin designer options

Tank volume sizing is an entirely different problem from pipe sizing and doesn't fit into the GA. There are multiple tank purposes and you would need to simulate a variety of EPS runs for fires and...

View Article

Forum Post: RE: Negative Pressures in Pipe

This wiki on negative pressures covers a lot of what Tom has mentioned in this postings: communities.bentley.com/.../10830.troubleshooting-negative-pressures-at-pumps-junctions-other-node-elements

View Article


Forum Post: RE: Pumps performance

Hello Bushra, It appears that the issue is related to the pumps pumping against a tank that is full. The pump status is still on, but this the pump is full (and there is no demand in the system), that...

View Article

Wiki Page: User Notification: Invert elevation on volume curve xxx.xx ft is...

Applies To Product(s): Bentley PondPack Version(s): 08.11.xx.xx Environment: N\A Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem A user notification is being...

View Article


Wiki Page: Understanding length/wave speed adjustments and their impact on...

Applies To Product(s): Bentley HAMMER Version(s): 08.11.XX.XX Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem When computing a transient simulation, the...

View Article

Wiki Page: Background layer causes program to crash

Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.xx.xx Area: Modeling Problem The application will crash when opening a model that has a...

View Article

Wiki Page: Long time to load background layers

Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS Version(s): 08.11.xx.xx Area: Layout and Data Input Problem When I try to insert the background file (.dxf), it either takes a very long time to...

View Article