Forum Post: RE: Off Elevation is less than or equal to the On Elevation
Hamid, Do you have a link to the hands-on-training, so I can have a look at it without having to search it out? Also, did my suggestions resolve your issue? I want to confirm that you were at least...
View ArticleForum Post: RE: Off Elevation is less than or equal to the On Elevation
Hands-on training in the "SewerGEMS/SewerCAD, Sewer System Modeling (metric)"Catagory -"Gravity and Pressure" part. (Please visit the site to view this file)
View ArticleForum Post: RE: Modeling DBP Formation in WaterCAD V8i
There are two general ways to model this with WaterGEMS. The simpler way is to model DBP formation as a constituent that grows to reach an equilibrium concentration. You would start with a calibrated...
View ArticleForum Post: RE: Serious Error 51007 SewerGEMS - Pipe/channel networks must...
Lee, What version of SewerGEMS are you using? You can check under Help > About SewerGEMS. The latest is 08.11.04.54. Changes that you make to an attribute that is stored in a child alternative...
View ArticleForum Post: RE: Modeling DBP Formation in WaterCAD V8i
Thank you for your reply. Only one thing I would like further clarification: the equilibrium concentration. That would be the concentration that would result after a very long time of being analyzed...
View ArticleForum Post: RE: Modeling DBP Formation in WaterCAD V8i
The equilibrium concentration is an input property for the model. The concentration will approach whatever value you enter. The rate constant determines how quickly you will reach it. You need to do...
View ArticleForum Post: WaterCAD / WaterGEM: Modelbuilder Message - Unable to Open Table
I'm trying to import the customer meter data in WaterGEM using Modelbuilder from a Word Excel document. When I try to import the data, the following message pops up. The name of the file appears with...
View ArticleWiki Page: Performing a silent installation for Bentley's Water products
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, Flowmaster, CulvertMaster, PondPack Version(s): Various Environment: N/A Area: Installation Subarea:...
View ArticleForum Post: RE: WaterCAD / WaterGEM: Modelbuilder Message - Unable to Open Table
I realized I need to sync, so I did. Then, I received the following messages. Which format do I need to change?
View ArticleForum Post: RE: WaterCAD / WaterGEM: Modelbuilder Message - Unable to Open Table
Hello Yoko, It looks like you may have used the "sync out" button in the modelbuilder manager. This is for exporting the data in the model to external file. It doesn't sound like this is what you...
View ArticleWiki Page: Modeling a Connection to an Existing System
Applies To Product(s): Bentley WaterGEMS, Bentley WaterCAD Version(s): 08.11.xx.xx Environment: N/A Area: Modeling Subarea: Original Author: Scott Kampa, Jesse Dringoli, Tom Walski How To: Model a...
View ArticleForum Post: RE: WaterCAD / WaterGEM: Modelbuilder Message - Unable to Open Table
Yoko, Can you please upload your spreadsheet so we can have a look at it? There are two options for sharing your files on BE Communities. If you would like the files to be visible to other members,...
View ArticleWiki Page: How do I activate a GEOPAK license inside StormCAD for MicroStation?
Applies To Product(s): Bentley StormCAD Version(s): 08.11.xx.xx Environment: N/A Area: Installation Subarea: Original Author: Scott Kampa, Bentley Technical Support Group Problem Description How do I...
View ArticleForum Post: RE: Off Elevation is less than or equal to the On Elevation
Hamid, I've had a look at the issue in the documentation that you stated you were using and as I suspected the problem is that the instructions that you are looking at are based on an older version of...
View ArticleWiki Page: FCV Caused ill conditioning.... (Solution 500000073219)
Applies To Product(s): Bentley WaterGEMS Version(s): 08.11.XX.XX Environment: N\A Area: Output and Results Subarea: N\A Original Author: Jesse Dringoli, Bentley Technical Support Group Problem What...
View ArticleForum Post: RE: WaterCAD / WaterGEM: Modelbuilder Message - Unable to Open Table
Thanks, Jesse and Mark. As I reviewed the spreadsheet, I realized that there are a lot of data missing. I don't know how that happened, but I will try to check that first. Thank you so much.
View ArticleWiki Page: Using Pipe Renewal Planner
Applies To Product(s): Bentley WaterGEMS Version(s): V8i SELECTSeries 2 Environment: N/A Area: N/A Subarea: N/A Original Author: Scott Kampa, Bentley Technical Support Group Overview The purpose of...
View ArticleForum Post: Troubleshooting fire flows in a model
I have a completed model but I am having difficulty in getting reasonable fire flows throughout the system. My model as built is generating some pretty high fire flows 3,500 gpm in areas where the...
View ArticleWiki Page: Where is the system head curve tool in HAMMER? (Solution...
Applies To Product(s): Bentley HAMMER Version(s): 08.11.xx.xx Environment: N\A Area: Modeling Subarea: N\A Original Author: Terry Foster, Bentley Technical Support Group Problem Where is the system...
View ArticleForum Post: RE: Troubleshooting fire flows in a model
Hello David, One possible reason is that the model is not calibrated to the system. In such a case, you might be seeing pressures that are higher than you would normally see. For instance, if the...
View Article