Forum Post: RE: Pump Selecting
Negative pressure can be due to several reasons, please see this support solution. It doesn't say that pump can’t deliver the flow or head.
View ArticleWiki Page: What is the meaning of the message "The difference between...
Applies To Product(s): Bentley PondPack Version(s): 10.00.XX.XX Environment: N/A Area: Calculations Subarea: Original Author: Terry Foster, Bentley Technical Support Group...
View ArticleForum Post: RE: Pump Selecting
Sushma Is inserting a useless reservoir to remove the Error Message (as I did above) correct or a better option can be suggested? Sim
View ArticleForum Post: Help With setting up a VSP or VFD with 4 pumps.
Hi, Working with SewerGEMs, GVF-Convex solver. I need your assistance in setting up a VSP or VFD with the below on and off (elevations) controls. I want to use the fixed head VSP type and use my...
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
The concept of a fixed head is fundamentally inconsistent with the idea of pumps coming on at different levels. Either you have a fixed head or you have pumps that come on at different heads. For this...
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
Good. So, if I decide to use option one which is the using the VSPB, what will be the optimum control level I need to use to accomodate all 4 pump settings? As you can see 4 pumps OFF and ON settings...
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
VSPB attempts to maintain a constant wet well level and will automatically turn pumps on and off to do so. It turns on an additional pump as soon as the current pumps can no longer keep up with inflow.
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
Ok. I am trying to set up the VSPB. What is the difference between Battery Pump Definition and a Constant Speed pump definition??
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
No difference, except that the one you select for the VSPB represents the pump definition of all the pumps in the battery whereas the one selected in the regular pump node represents that single pump....
View ArticleWiki Page: How do I input the elevations for an irregular weir cross section...
Applies To Product(s): Bentley SewerGEMS, Bentley CivilStorm, Bentley PondPack Version(s): 08.11.04.54 Environment: N\A Area: Modeling Subarea: N\A Original Author: Mark Pachlhofer, Bentley Technical...
View ArticleForum Post: Negative Demand
Hello Is HGL of a Junction that has a negative Demand equal to HGL of lowest Tank or Reservoir of the network? Sim
View ArticleForum Post: Darwin Scheduler
Hello 1- In ‘Pumps to Optimize’ Tabs (In ‘Darwin Scheduler’), we can specify Pumps as ‘VSP’ or not (Decision Type column), in spite of specifying it before in property grid of those Pumps. Why we do...
View ArticleForum Post: RE: Negative Demand
Can you attach the model that you used to test this? Regards, Mal
View ArticleForum Post: RE: Darwin Scheduler
The 'Decision Type' in Darwin Scheduler is independent of the setting in the main application. If you pick a pump for use in Scheduler you can specify whether you want it to act as a fixed speed pump...
View ArticleForum Post: RE: Negative Demand
Dear Mal Actually this question is sequel of the topic which you can read it and see the model here: communities.bentley.com/.../300764.aspx Have a look at model please. Mark suggested an idea to...
View ArticleForum Post: RE: Negative Demand
Mal Have a look at this adapted model, run it and see what happens: R-3 has the lowest HGL between Reservoirs (ignore R-1) which is 10 m. Just J-3 and J-5 have HGL more that 10 m and these two...
View ArticleForum Post: RE: Reading Transient Results Viewer From WO.NET
Hi Jesse, I just uploaded the file following the instructions of the link you sent to me yesterday. I uploaded two files: a .zip file with my source code (called "ProgramaTesis_V01 - Bentley") and a...
View ArticleForum Post: RE: Reading Transient Results Viewer From WO.NET
Thanks for sending the files. We received them and will take a look shortly.
View ArticleForum Post: RE: Help With setting up a VSP or VFD with 4 pumps.
Jesse and Tom - I went with Tom's recommendation (option 2) which is setting up individual pumps each with several control statements along the lines of IF(Level x and Level y) THEN Pump setting =...
View ArticleForum Post: RE: Reading Transient Results Viewer From WO.NET
Jessica, Here are some recommendations based on a review of the source code: 1. Consider simplifying the approach. Don’t try to create an application (i.e. custom ApplicationModel, ParentFormModel,...
View Article