Applies To Product(s): Bentley SewerGEMS, Bentley CivilStorm, Bentley PondPack Version(s): 08.11.04.54 Environment: N\A Area: Modeling Subarea: N\A Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Description How do I input the elevations for an irregular weir in composite outlet structures? Steps to Resolve The inputs for the elevations of an irregular weir cross section are based upon the invert elevation which is assigned to the weir located here: Any value you put in the cross section table is added to the invert elevation that you define. Therefore, if you just wanted to enter the physical elevation of the weir in the cross section table you'd enter the invert elevation as 0.
↧