Wiki Page: How do I download WaterGEMS, WaterCAD, HAMMER, SewerGEMS,...
Applies To Product(s): Bentley WaterGEMS, Bentley WaterCAD, Bentley HAMMER, Bentley SewerGEMS, Bentley SewerCAD, Bentley StormCAD, Bentley CivilStorm, Bentley FlowMaster, Bentley PondPack,...
View ArticleForum Post: RE: WaterGEMS Skelebrator Technical Manual
Hello Kramos, During Smart Pipe Removal in Skelebrator, demands on removed nodes will be reallocated to the nearest node. You can find more information on Skelebrator under Help WaterGEMS Help...
View ArticleForum Post: RE: Choice of Solver for Sanitary loading (no storm event)
Hi Sushma, Sorry for the late response. When i modelled gravity networks alone, i could use as many outfalls as required. The model is running fine in gravity now. All other difficulties got...
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
Magg, You need to upgrade the software ont other rmachine, so that it uses the same version as the machine that is able to open the project. in order to find out what version is on the other machine...
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
Hi Mark, Thanks. We will try to upgrade the software. And another question, we have a machine with newer version series 4, but when I tried to open the model on it, error occurred like “unexpected...
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
Hi Mike, Another question about discharge pressure setting ~ As shown above, if it is possible to share the same pump station with two discharge pressure setting? Or it is the reason cause...
View ArticleForum Post: shareing the same pump station with two different pressur setting?
Hi, Another question about discharge pressure setting ~ As shown above, if it is possible to share the same pump station with two discharge pressure setting? Or it is the reason cause error? Coz...
View ArticleForum Post: Geo-referencing
Hi, I loaded a geo-referenced background aerial photo (.bmp + .bpw) and a preliminary pipe alignment shape file into WaterCAD. But apparently the two background layers don't line up in WaterCAD. Note...
View ArticleForum Post: RE: SRV with acceleration
Hi, Thank you for your response. My reference to "include" was to ask if Hammer can take into account the additional force (and time delay) for opening the valve (due to the valves inertia). My...
View ArticleWiki Page: Modeling a submersible pump
Applies To Product(s): Bentley HAMMER, Bentley WaterGEMS, Bentley WaterCAD Version(s): 08.11.xx.xx Environment: N\A Area: Modeling Subarea: N\A Original Author: Scott Kampa, Bentley Technical Support...
View ArticleForum Post: RE: Geo-referencing
Hi WaterModeler, I assume, by WaterCAD you mean StandAlone (SA) WaterCAD and SA doesn't understand any coordinate system or projection. What it knows is plane X and Y values. So, if two files are in...
View ArticleForum Post: RE: Geo-referencing
Re: Exporting to shapefile, You can do that by going to Flextable. From View Flextables, open up the table you like and first icon on top left will allow you to export to a shapefile. This link will...
View ArticleForum Post: RE: Pressure increasing in pipes due to water hammer
Hi, Thank you so much for your answer. Now the model is working, and it is really close to the experiment. I have an other question: How Bentley Hammer is knowing the dimension of hydraupneumatic tank...
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
We have a machine with newer version series 4, but when I tried to open the model on it, error occurred like “unexpected drawing version 40”. What can I do to get it fixed for this situation? thanks...
View ArticleForum Post: RE: Rain File
SMIAH, What program are you looking to use this data in? What will this data be used for? Are you trying to create storm data as in StormCAD?
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
As shown above, if it is possible to share the same pump station with two discharge pressure setting? Or it is the reason cause error? Coz in my model when I run FF scenario, it results in “failed to...
View ArticleForum Post: RE: DISEÑO DE LINEA DE CONDUCCION Y RED DISTRIBUCION CON WATERCAD
Gracias Maria por tu tiempo, mi duda es como pudiera modelar una camara distribuidora de caudales en el Watercad ya que solo biene camara rompedora de presion y cual es el correcto uso de las valvulas...
View ArticleForum Post: RE: Geo-referencing
Yes, stand-alone is what I am suing now. Re-projection works for shape files (alignment and topo) but not for .bmp image file. I was able to line up the image file including the .bpw Coordinate file...
View ArticleForum Post: RE: .wtg.mdb file missing when i save the model under SELECT series4
Hi Mark, Thanks for help. Please see below as the screenshot, hope it works this time. What I was trying to do is sharing a same group of pump to service two different area with separated...
View Article