Forum Post: RE: Darwin Calibration

$
0
0
For the first question, I think you're saying that the number of leakage nodes shown at the top part of the solution is 9, but you see more than 9 entries in the list of adjustments at the bottom? The screenshot is a bit fuzzy, but it looks like some of the junction emitter coefficients were not changed from their original values. Are there 9 emitter coefficients that were changed? (between the original and adjusted values shown in the table) For the ones that had values for original emitter coefficient, is it expected that these should have positive values before calibration?