Forum Post: RE: Inlet Capture Efficiency Question

Hello Minimum System Requirements, We seem to be having difficulty contacting you via your service request, so I wanted to provide some general feedback on your forum post here based on the...

View Article


Forum Post: RE: watercad/gem entering elevation at each node

Actually, on further inspection, it seems that there is a single duplicate value in the Value field. The 'key field' values should all be unique, so you will need to add an ID field in Excel as...

View Article


Forum Post: RE: Why GA?

WaterGEMS doesn't use genetic algorithms to solve the network hydraulic equations. Instead it uses a gradient algorithm (see the WaterGEMS Help for more details). WaterGEMS does use genetic algorithms...

View Article

Forum Post: RE: ArcMAP MXD loses link to SewerGEMS project file

Rdueck, It looks like I'm having trouble reproducing this one. Here is what I have tried so far given your steps: Attempt 1: Follow your instructions for steps 1-7 exactly using a new geodatabase and...

View Article

Wiki Page: System.OutOfMemoryException when viewing graphs or saving a model...

      Applies To        Product(s): Bentley WaterGEMS   Version(s): 08.11.03.19   Environment:  N\A   Area:  General   Subarea:  N\A   Original Author: Jesse Dringoli, Bentley Technical Support Group...

View Article


Wiki: Hydraulics and Hydrology - Wiki

View Article

Blog Post: Meet Jonathan Smith – Bentley LEARNing Conference Trainer

Jonathan will be presenting several courses in the Hydraulics and Hydrology track at the Bentley LEARNing Conference in Birmingham, UK. His sessions include: Introduction to Subsurface Utilities...

View Article

Wiki Page: "Unexpected drawing version..." error when opening model

      Applies To        Product(s): Bentley WaterCAD, WaterGEMS, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm   Version(s): 08.11.XX.XX   Environment:  N/A   Area:  Other   Subarea:    Original...

View Article


Wiki Page: How do I batch merge nodes in close proximity?

Applies To Product(s): Bentley WaterCAD, Bentley WaterGEMS, Bentley HAMMER Version(s): 08.11XX.XX Environment: N/A Area: Layout and Data Input Subarea: Original Author: Mark Pachlhofer, Bentley...

View Article


Wiki Page: Controls for alternating between multiple pumps (Solution...

      Applies To        Product(s): Bentley WaterGEMS, Bentley WaterCAD   Version(s): 08.11.xx.xx   Environment:  N\A   Area:  Modeling   Subarea:  N\A   Original Author: Scott Kampa, Bentley Technical...

View Article

Forum Post: Pipe run not defined as continuous pipe list Message - Flushing Run

Received subject message after running flushing event.  Is there a way to identify where the break in the pipe run occurs?  The "Select All Elements with Message id 41848" is grayed out in the User...

View Article

Wiki Page: Why are there so many extra element types listed for WaterGEMS and...

      Applies To        Product(s): Bentley WaterGEMS, Bentley WaterCAD   Version(s): 08.11.xx.xx   Environment:  N/A   Area:  Layout and Data Input   Subarea:    Original Author: Scott Kampa, Bentley...

View Article

Wiki Page: General WaterGEMS V8 [FAQ]

      Applies To        Product(s): Bentley WaterGEMS, Bentley WaterCAD   Version(s): V8 XM, V8i    Environment:  N/A   Area:  N/A   Subarea:  N/A   Original Author: Jesse Dringoli, Bentley Technical...

View Article


Forum Post: RE: Pipe run not defined as continuous pipe list Message -...

Matthew, I'm not sure what Message ID 41848 says, but I have a few ideas of what you might want to try if the problem is finding a break in the pipe run. Try color coding your pipes based on the field...

View Article

Forum Post: batch pipe split not working - "Object reference not set to an...

Hello, I'm having trouble performing batch pipe splits on a portion a distribution network.  The vast majority of the network worked fine with batch pipe split but one area gives the message "Object...

View Article


Forum Post: RE: Pipe run not defined as continuous pipe list Message -...

41848 is just the message associated with the detected break in the flushing pipe run.

View Article

Forum Post: RE: Pipe run not defined as continuous pipe list Message -...

Thank you for the responses.  Mark, your suggestion was helpful in trying to figure this out.  It appears that I received the error as a result of defining the pipe set in such a way that the...

View Article


Forum Post: RE: Pipe run not defined as continuous pipe list Message -...

Good to hear you were able to figure that out Matt. I was actually in the process of creating another post that points out exactly where you found the problem to be, but I got side tracked with a few...

View Article

Forum Post: RE: ArcMAP MXD loses link to SewerGEMS project file

Thanks for your efforts,  MPachlhofer. I am 99% sure that I have always followed the 7 steps you outlined. If I encounter the problem again and realize, if anything, I did differently, then I will be...

View Article

Wiki Page: Modeling A Pump Start-Up Transient Event In Bentley HAMMER V8i [TN]

      Applies To        Product(s): Bentley HAMMER V8i   Version(s): 08.11.00.30   Environment:  N/A   Area:  Modeling   Subarea:  N/A   Original Author: Jesse Dringoli, Bentley Technical Support Group...