Wiki Page: Does HAMMER support initially negative pressures? (Solution 500000056897)

$
0
0
      Applies To        Product(s): BENTLEY HAMMER   Version(s): N\A   Environment:  N\A   Area:  Modeling   Subarea:  N\A   Original Author: Jesse Dringoli, Bentley Technical Support Group           Problem Does HAMMER support initially negative pressures? Problem Number 29948 Solution Yes, it does, but there are two things to consider: 1) Make sure the pressure is not negative at demand nodes; 2) Make sure the pressure is not below the vapor pressure limit (initially) (Both of these refer to initial conditions) See Also