Forum Post: RE: Time duration assist pump

$
0
0
Hello Busher, It should be possible, but you may have to get a bit creative. See below wiki article for an example of how to set up a "timer" device: Creating a timer control to execute after a specific time period has elapsed There is also the option of manually controlling the pumps by way of a pump Pattern. This is done by selecting "True" for "Is Variable Speed Pump", "Pattern Based" as the "VSP Type", then set up and select the pattern (1.0 = on, 0.0 = off). You can also set up pump controls based on clock time: How to model timed pump starts, such as a certain on-and-off cycles per hour