Wiki Page: Setting up a Runaway speed scenario for a turbine

$
0
0
      Applies To        Product(s): Bentley HAMMER   Version(s): 08.11.04.58   Environment:  N\A   Area:  Modeling   Subarea:  N\A   Original Author: Jesse Dringoli, Bentley Technical Support Group         Problem How can I set up a scenario to model a "runaway" condition for a turbine? (turbine speeding up without wicket gates closing) With instant load rejection, the operating rule is required to go from 100% to 0% open. Solution To model an instant load rejection without closing the wicket gates (to check for runaway speed), set up the operating rule to be at a constant 100% open for the entire simulation duration (as specified in the calculation options) , then close it to 0% open at a time after the end of the simulation. See example below where the simulation duration is, say, 150 seconds: