Forum Post: RE: query in solving one notification

$
0
0
Actually, SewerGEMS can have more than one outfall in a network, but you must ensure that you are doing a 'dynamic wave' analysis. To do this, set the Active Numerical Solver field in the Calculation Options to 'Implicit (SewerGEMS Dynamic Wave)' or 'Explicit (SWMM Solvers)'. (Note: if using SWMM, make sure the Routing Method is set to Dynamic Wave). Regards, Mal