Wiki Page: What are the limitations of importing/exporting EPANET files?

$
0
0
Applies To Product(s): WaterCAD, WaterGEMS Version(s): 10.00.xx.xx, 08.11.xx.xx Area: Layout and Data Input Original Author: Terry Foster, Bentley Technical Support Group When we do an import/export with EPANET files the only data that will be retained or unaltered is the data that is supported in both EPANET INP format and WaterGEMS or WaterCAD. Items in WaterGEMS and WaterCAD that are not supported in EPANET: VSPs VSPBs Fire Flow Flushing Pressure Dependent Demands Variable reporting time steps Demand/Roughness Adjustments Continuous patterns Elements like Hydropneumatic tanks, air valves, etc. Top-filling options for a tank All HAMMER properties User data Energy costs All presentation settings Isolating valves/criticality All ModelBuilder, LoadBuilder, Darwin, TRex and Skelebrator settings Spot-elevations Isolation Valves Pump curves (EPANET exporter generates a CURVE. However such curves are always imported back - during round-trips - as multi-point pump definition. So if the original pump-definition was a 1-point or 3-point curve the round-trip may not come back to the exact original pump definition type.) Unit Demands Selection Sets Queries Graphs Data from extensions (Calibrator/Designer/Capital-cost) Customer meters Tap/Laterals One other thing that happens when importing EPANET files is that two extra pipes are added for every directed node. They are labeled as something similar to "was added during EPANET import". So when the WaterGEMS or WaterCAD model thus created is exported back to EPANET those extra pipes are removed and the original directed node is rebuilt without the extra pipes. Pumps and Valves Pumps and valves are seen as link elements in EPANET, whereas WaterCAD and WaterGEMS see them as nodes. Therefore on export to EPANET, a new link element must be created to use as the pump/valve. To do that, two overlapping junctions are created to connect to it. The link in EPANET will have the same name as the pump/valve did in WaterCAD or WaterGEMS. In EPANET, an icon will display for the pump and valve, but when trying to double-click on it, the junction could be selected by mistake. For Example, take a look the following valve in WaterGEMS/WaterCAD: Here's what it looks like after exporting to and opening in EPANET: When hovering the mouse over, it may look as if it's a junction: However if you click and drag, you'll see its actually two junctions overlapping (at the original location of the valve in WaterGEMS/WaterCAD) with the PRV link element between them: See Also Should the EPANET solver and the WaterGEMS solver give the same results for a model? What are the difference between WaterGEMS/CAD and EPANET?

Viewing all articles
Browse latest Browse all 39611

Latest Images

Trending Articles



Latest Images

<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>