Applies To Product(s): Bentley WaterGEMS, Bentley SewerGEMS, Bentley CivilStorm, Bentley StormCAD, Bentley PondPack, Bentley StormCAD, Bentley HAMMER, Bentley WaterCAD Version(s): 08.11.03.84 Environment: N/A Area: Layout and Data Input Subarea: Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Description Using modelbuilder I get a user notification that says, "Error: Unable to create Conduit Conduit_Name start and/or stop node could not be found. Ensure that either the start or stop fields have been mapped..." and my conduits are not created. Resolution In step 2 of modelbuilder make sure that you have the, "Establish connectivity using spatiall data" option is checked. The default tolerance is 1 ft., but can be made larger if needed. I larger number usually means your GIS data was not created using the snapping option with ensures all the lines and points are linked together. In step 2 you might also want to check to the "Create nodes if none found at endpoints" option if it is applicable to what you would like to do.
↧